How Much Does Aluminum Coil Weigh?
Every gutter contractor, fabricator and freight forwarder eventually asks the same question: how much does a coil of painted aluminum actually weigh? The answer decides your freight quote, your warehouse floor loading, whether your forklift can pick it up, and — if you buy by the foot and sell by the tonne — your margin. This guide gives you the formula, a ready-to-use weight chart for common gauges and widths, and the three details (coil OD, alloy, coating) that quietly change the number by ±5%.
The Weight Formula: One Line Does Everything
Aluminum coil weight comes from a single equation:
Weight (kg) = Length (m) × Width (m) × Thickness (mm) × Density
where density for common aluminum alloys is:
| Alloy Series | Density (kg/m³) | Notes |
|---|---|---|
| 1100 / 1xxx (pure Al) | 2,710 | Purest, lightest |
| 3003 / 3005 / 3105 (Al-Mn) | 2,730 | Standard for gutter and roofing coil |
| 5052 (Al-Mg) | 2,680 | Higher strength, slightly lighter |
Per-unit shortcuts for quick mental math:
- kg per square metre = thickness (mm) × 2.71 (for 3xxx alloys; × 2.73 including standard coating). A 0.7 mm coil: ≈ 1.90 kg/m².
- Weight per foot (North America) = thickness (inches)² × width (inches) × 12.1 lb for 3xxx alloys — or just use the chart below.
Painted Aluminum Coil Weight Chart (Metric)
Weights below are theoretical for 3xxx alloy with a standard PVDF coating (~2.73 kg/m³ effective). Multiply by coil length to get total weight.
| Thickness | kg per m² | 1,000 mm wide (kg/m) | 1,220 mm wide (kg/m) | 1,250 mm wide (kg/m) |
|---|---|---|---|---|
| 0.5 mm | 1.37 | 1.37 | 1.67 | 1.71 |
| 0.6 mm | 1.64 | 1.64 | 2.00 | 2.05 |
| 0.7 mm | 1.91 | 1.91 | 2.33 | 2.39 |
| 0.8 mm | 2.18 | 2.18 | 2.66 | 2.73 |
| 1.0 mm | 2.73 | 2.73 | 3.33 | 3.41 |
| 1.2 mm | 3.28 | 3.28 | 4.00 | 4.10 |
Painted Aluminum Coil Weight Chart (Imperial — Gutter & Roofing Gauges)
For North American buyers working with decimal-inch gauges, per-foot weights for the most common coil widths:
| Thickness | 11.75″ blank (lb/ft) | 15″ blank (lb/ft) | 16″ blank (lb/ft) | 20″ blank (lb/ft) |
|---|---|---|---|---|
| 0.019″ | 0.52 | 0.66 | 0.71 | 0.89 |
| 0.024″ | 0.65 | 0.83 | 0.89 | 1.11 |
| 0.027″ | 0.73 | 0.94 | 1.00 | 1.25 |
| 0.029″ | 0.79 | 1.01 | 1.08 | 1.34 |
| 0.032″ | 0.87 | 1.11 | 1.19 | 1.48 |
| 0.040″ | 1.09 | 1.39 | 1.48 | 1.86 |
Worked example: a full pallet order of 0.032″ × 11.75″ coil for a 5K gutter run — 500 m (1,640 ft) weighs roughly 650 kg (1,433 lb) of metal, plus about 15 kg for the steel core and wooden cradle. That is a two-person lift without a forklift — plan your unloading accordingly.
Why Your Scale Might Disagree by ±5%
Calculated weight is theoretical. Real delivered weight differs for three legitimate reasons:
1. The Coil Core and Packaging
A standard steel core (508 mm ID) weighs 8–12 kg depending on gauge; the export cradle and moisture-barrier packaging add 10–20 kg. Freight invoices bill gross weight — always confirm whether a quotation is net coil weight or gross shipping weight.
2. Thickness Tolerance
Mills roll to tolerance, typically ±0.01–0.02 mm on coil. A full tonne of “0.7 mm” coil delivered at 0.71 mm weighs 1.4% more metal — and at LME-driven pricing, you pay for exactly what you receive. Over-tolerance metal is not a defect; it is how rolling works. If a budget is thickness-sensitive, agree a tolerance class in the contract.
3. The Coating Layer
A 25 μm PVDF system adds roughly 0.07 kg/m² — under 4% on a 0.7 mm coil. Theoretically the paint weight is priced into the coating fee, but on big orders it shows up on the scale. Ignore it for estimates, include it for verification weighing.
Weight Is Money: Three Practical Consequences
Freight Planning
Ocean freight for coil is billed by weight or volume, whichever earns more. Painted coil is dense, so weight governs: a 20-ft container legally maxes out around 24–26 tonnes of payload. In practical terms, that is roughly:
- ≈ 12,000 m² of 0.5 mm coil, or
- ≈ 8,500 m² of 0.7 mm coil, or
- ≈ 6,700 m² of 0.9 mm coil.
If your order sits just over one container, ask your supplier to quote “as per loading plan” — a mill that strips coils and re-packs tightly can sometimes fit the same tonnage into fewer containers. Our price guide covers how freight terms change the invoice.
Buying by Length vs Buying by Weight
Gutter contractors buy length (feet of finished gutter) but pay for weight. This is exactly why thickness matters so much to your margin — every 0.003″ of gauge adds ~11% to your metal cost per foot. The full gauge comparison is in our 0.027 vs 0.029 vs 0.032 gutter coil guide.
Warehouse and Handling Safety
Floor loading and forklift capacity are weight questions: a full jumbo coil of 1.2 mm × 1,250 mm × 2,000 m runs about 8.2 tonnes — beyond most shop forklifts. Know the weight before it ships, and tell your warehouse team what is coming.
Quick Reference: Common Coil Order Weights
| Product | Spec | Typical Coil Length | Approx. Net Weight |
|---|---|---|---|
| Gutter coil (5K) | 0.027″ × 11.75″ | 500 m | ≈ 530 kg |
| Gutter coil (6K commercial) | 0.032″ × 11.75″ | 500 m | ≈ 630 kg |
| Roofing coil | 0.8 mm × 1,000 mm | 1,000 m | ≈ 2,180 kg |
| Facade panel stock | 1.0 mm × 1,220 mm | 1,000 m | ≈ 3,330 kg |
| Jumbo mill coil | 1.2 mm × 1,250 mm | 2,000 m | ≈ 8,200 kg |
Frequently Asked Questions
How do I calculate the weight of aluminum coil?
Multiply length × width × thickness × density. For 3xxx series painted aluminum, density with standard coating is about 2.73 kg/m³. In metric: kg = length(m) × width(m) × thickness(mm) × 2.71, then add ~1% for coating. In imperial: lb = thickness(in) × width(in) × length(ft) × 0.101 per inch of thickness per ft²… or simply use the charts above.
How much does a 500-foot roll of gutter coil weigh?
0.027″ × 11.75″ gutter coil at 500 ft (152 m) weighs about 125 kg (275 lb) net. The same length in 0.032″ weighs about 145 kg (320 lb). Add 5–8 kg for the core and packaging.
How much does aluminum weigh per square metre?
Multiply thickness in mm by 2.71. So 0.7 mm aluminum is 1.90 kg/m², 0.8 mm is 2.17 kg/m², and 1.0 mm is 2.71 kg/m² — before adding the coating layer.
Does the paint coating change the coil weight much?
Not much: a standard PVDF system adds roughly 0.07–0.09 kg/m², about 3–4% on a 0.7 mm coil. The bigger verification factors are the steel core (8–12 kg) and packaging (10–20 kg per coil).
How many tonnes fit in a 20-foot container?
Painted aluminum coil is weight-limited, not volume-limited: plan on 24–26 tonnes of payload per 20-ft container depending on road limits at destination. Ask your supplier for a loading plan — coil orientation and blocking affect the final number.
Getting Weights and Prices That Match Your Order
Weight math is the difference between a freight surprise and a clean landing. When you request a quotation from Yatai Aluminum, we state net coil weight, gross shipping weight and loading plan for your exact specification — alloy, gauge, width and length — so your freight forwarder and your accountant both get real numbers. Send us your sizes and destination port, and we will quote with the weights calculated, not estimated.




One comment
[…] convert tonnage into product, use our coil weight charts: a 20-ft container holds roughly 8,500 m² of 0.7 mm coil, or 12,000 m² of 0.5 mm coil, or 6,700 […]